Magnetostrictive I.S. probes XMT SI 485 (Intrinsecally safe version)
Stainless Steel Enclosure Ø 50 mm IP68 (submersible up to 1,2 m per 24 hours).
In 2” riser installation
7/8" circular connector with standard cable length 2 m. Ø 9 mm, hydrocarbon resistant in according ENI specification.
Power supply: 12 VDC - RS485 serial port.
I.S. circuits to wire to an intrinsically safe barrier active (BRA-SI) or passive (BRA-SIP)
Calculation of data relating to:- Product level in 0,01 mm - Interface level in 0,01 of mm. (water presence detection) - Product mean temperature up to max. 5 integrated digital sensors. Standard measuring accuracy: +/- 0,5 mm. Standard resolution: +/- 0,01 mm. Temperature accuracy range -20 +70 °C: +/- 0,2 °C Temperature resolution: ± 0,0625 °C
Wireless I.S.XMT-RF Probes (Intrinsecally safe version battery operated)
Wireless transmission to the RF receiver up to 2 Km. line of sight
RF repeater for difficult environmental application
Wake up on radio function
Power up 500 mW adjustable
RF signal measurement and display
Calculation of data relating to:
- Product level in 0,01 mm - Interface level in 0,01 of mm. (water presence detection) - Product mean temperature up to max. 5 integrated digital sensors. Standard measuring accuracy: +/- 0,5 mm. Standard resolution: +/- 0,01 mm. Temperature accuracy range -20 +70 °C: +/- 0,2 °C
Temperature resolution: ± 0,0625 °CBlack Seal Magnetostrictive Probe (Theft-proof magnetostrictive level probe with memory, integrated floats)
This Magnetostrictive probe belongs to the same family of XMT-SI-485 with data logger functionality which is automatically activated when the external power supply and/or data go off. When external power supply is present, as the normal case, probe works as usual replying to the polling protocol. When the power/data go off, an internal battery is automatically connected to the electronic and starts to store movement data into its internal memory keeping lately available for download. This option is available both for the new probes for the old probe as a retrofit
Radio wireless, Battery powered
Wired RS485 LOG: Tank level data saving in case of power failure, 1 month of memory
When external power supply is operational, as the normal case, the probe operates as usual in polling mode. With no power/data, an internal battery is automatically connected to the electronics which begins memorizing data movements in its internal memory for subsequent downloading on restoring of normal operation condition.
Magnetostrictive LPG probes (Intrinsecally safe version)
Stainless Steel Enclosure Ø 50 mm IP68 (submersible up to 1,2 m per 24 hours).
In 2” riser installation
7/8" circular connector with standard cable length 2 m. Ø 9 mm, hydrocarbon resistant in according ENI specification.
Power supply: 12 VDC - RS485 serial port.
I.S. circuits to wire to an intrinsically safe barrier active (BRA-SI) or passive (BRA-SIP)
Calculation of data relating to:- Product level in 0,01 mm - Interface level in 0,01 of mm. (water presence detection) - Product mean temperature up to max. 5 integrated digital sensors. Standard measuring accuracy: +/- 0,5 mm. Standard resolution: +/- 0,01 mm. Temperature accuracy range -20 +70 °C: +/- 0,2 °C Temperature resolution: ± 0,0625 °C
Probes Accessories I.S. IP68 Junction Box
An high IP rated multi-way connector box suitable for filling with bi-component gel to wiring magnetostrictive probes and sensors.
2 or 4 cable entry versions
Enclosure material: PA66 hydrocarbon resistant
Cable glands material: Geolast entries max. Ø 9,5 mm
Screw terminal blocks 5 poles, Temperature: -20 °C / +125 °C
Probes Accessories Ex d IP68 Junction Box
Die Cast aluminium junction box.
IP68 protection degree with terminal strip
Bracket for wall mounting
No 4 IP68 ½” cable glands
FTZU 07ATEX 0184X II 2GD Ex d tD IIC T4-T6 certification